GB/T 33594-2025

Application Scenarios

Advantages

• Anti-disconnection design for safety and reliability
• Lightweight and highly flexible, suitable for diverse fast-charging scenarios
• Comprehensive range of certifications
• Mature production lines for all specifications
• Customised product solutions tailored to client requirements

Standard

GB/T 33594-2025

Certification

CQC Certification

 

Certificate Numbers:

CQC23011401058

CQC17011174918

CQC15011128394

General Specification

Contact OMG Cable Specialists for the latest cable specifications

Cable Characteristics

Electrical Reliability Test

Item

Request

Test Method

Rated Voltage

DC 1000V

/

Reted Temperature

-40℃~ +90℃

/

Conductor Resistance(at20℃)

50mm²≤0.386Ω/km;6mm²≤3.3Ω/km;2.5mm²≤7.98Ω/km;0.5mm²≤39Ω/km

GB/T3956

Insulation Resistance

20℃≥3670MΩ.km;90℃≥3.67MΩ.km

GB/T 33594

Dielectric

Power Core: 8.4KV DC/5min; Control Core 3.6KV DC/5min.

GB/T 33594

Bending Radius Min.

≥6*OD

/

Flame Test

Complies with the vertical flame spread test

GB/T18380.12

Insulation tensile strength

Before aging 10MPa;After aging (135°C/168 hours),Change rate ≤ ±25%

GB/T 2951

Insulation Elongation

Before aging 300%;After aging (135°C/168 hours),Change rate ≤ ±25%

GB/T 2951

Jackets tensile strenqth

Before aging 10MPa;After aging (135°C/168 hours),Change rate ≤ ±25%

GB/T 2951

Jackets Elongation

Before aging 300%;After aging (135°C/168 hours),Change rate ≤ ±25%

GB/T 2951

Resistance against chemicals

Mineral oil (IRM902), winding without cracking

GB/T 33594

Resistance Against acid and alkaline

Soaked in oxalic acid and NaOH solution for 168 hours, tensile strength change rate ±30%; elongation ≥100%.

GB/T 33594

Cold Bending Test

-40°C,No cracking

GB/T 2951

Hot Shock Test

150℃/1H,No cracking

GB/T 2951

Crushing Test

≥11.0kN

GB/T 33594

Specifications

Certified Model

Specifications

Reference Current

Outer Diameter of Cable (TPE Sheath)

Outer Diameter of Cable (TPU Sheath)

Packaging

EVDC-(R)SS
EVDC-(R)SSPS
EVDC-(R)S90S90
EVDC-(R)S90S90PS90
EVDC-(R)S90U
EVDC-(R)S90S90PU
EVDC-(R)EYU
EVDC-(R)EYUPU
EV-(R)S90S90

 

 

 

 

 

 

 

 

 

 

 

 

2×16+…

63A

19.8-25.1

16.4-20.9

Packaging can be customised upon request.

 

 

 

 

 

 

 

 

 

 

 

 

2×20+…

80A

23-28

19-24

2×25+…

100A

24.5-31

20.7-26.3

2×35+…

125A

27.7-35

23.8-30.1

2×50+…

150A

32.4-40.9

27.9-35.3

2×70+…

250A

37.1-46.8

32.4-40.9

2×80+…

250A

41-52

36-45

2×95+…

350A

41.8-52.7

36-45.4

4×25+…

150A

32.4-40.9

27.9-35.3

4×35+…

250A

37.1-46.8

32.4-40.9

4×40+…

250A

40-52

36-46

4×50+…

300A

41.8-52.7

36-45.4

4×60+…

400A

46-57

40-50

The cable outer diameter conforms to the standard specified outer diameter, subject to our company’s specification sheet. The final outer diameter may vary significantly depending on the specifications and number of signal wires.