Application Scenarios
Advantages
• Wide voltage and scenario compatibility, suitable for multiple device types
• Resistant to extreme temperatures, oils, acids, alkalis, water, abrasion and cracking, adaptable to diverse slow-charging scenarios
• Mature automated factory production lines offering cost-effective cabling solutions
• Tailored slow-charging solutions provided according to specific client requirements
Standard
IEC 62893-3
EN50620
Certification
TÜV Certification
Certificate Numbers:
R 50436193 0004
R 50436194 0005
General Specification
Contact OMG Cable Specialists for the latest cable specifications
Cable Characteristics
|
Performance Request |
||
|
Item |
Request |
Test Method |
|
Rated Voltage |
450/750V |
— |
|
Rated Temperature |
-40~90℃ |
— |
|
Conductor Resistance(at 20℃) |
4mm²≤4.95Ω/km;0.5mm²≤39Ω/km |
IEC 60245-2 |
|
Insulation resistance |
20℃时≥7.1MΩ.km;90℃时≥0.007MΩ.km |
IEC 60245-2 |
|
Dielectric |
2.5KV AC/5min,NO Breakdown |
IEC 60245-2 |
|
Bending Radius Min. |
≥6 OD. |
— |
|
Flame Test |
Single cable flame test |
IEC 60332-1-2 |
|
Insulation tensile strength |
Before Aging 8Mpa; After Aging(135℃/168H)Variation<±30% |
IEC 60811-501 IEC 60811-401 |
|
Insulation Elongation |
Before Aging 200%; After Aging(135℃/168H)Variation<±30% |
IEC 60811-501 IEC 60811-401 |
|
Jacket tensile strength |
Before Aging 20Mpa; After Aging(110℃/168H)Variation<±30% |
IEC 60811-501 IEC 60811-401 |
|
Jacket Elongation |
Before Aging 300%; After Aging(110℃/168H)Variation<±30% |
IEC 60811-501 IEC 60811-401 |
|
Oil Resistance Test |
IRM 902#,100℃/7*24H,Tensile Strength Variaion<±40%,Elongation Variaion<±30% |
IEC 60811-404 |
|
Resistance Against acid and alkaline |
23℃ 5H Tensile Strength,Variaion<±40%;Elongation at break>100% |
IEC 60811-404 |
|
Impact test |
-40℃,no break |
IEC 62893-2 |
|
Hot set test |
200℃/15min Mechanical stress 20N/cm²,Maximum permanent deformation after cooling<25% |
IEC 60811-507 |
Specifications
|
Standard |
Specifications |
Outer diameter of twisted main core wire conductor |
Main conductor resistance (at 20°C) |
Reference Current |
Finished external diameter |
Packaging |
|
62893IEC121
|
3×1.5+px0.5…1.0+qx0.5…1.0 |
1.6 Ref. |
≤13.3 |
10A |
Structure designed to meet standards and customer requirements | As per the order or as agreed |
|
3×2.5+px0.5…1.0+qx0.5…1.0 |
2.1 Ref. |
≤7.98 |
16A |
|||
|
62893IEC123
|
3×1.5+px0.5…1.0+qx0.5…1.0 |
1.6 Ref. |
≤13.3 |
10A |
||
|
3×2.5+px0.5…1.0+qx0.5…1.0 |
2.1 Ref. |
≤7.98 |
16A |
|||
|
3×4+px0.5…1.0+qx0.5…1.0 |
4.0 Ref. |
≤0.272 |
20A |
|||
|
3×6+px0.5…1.0+qx0.5…1.0 |
3.2 Ref. |
≤7.98 |
32A |
|||
|
3×10+px0.5…1.0+qx0.5…1.0 |
4.5 Ref. |
≤1.91 |
40A |
|||
|
3×16+px0.5…1.0+qx0.5…1.0 |
5.7 Ref. |
≤1.21 |
63A |
|||
|
3×25+px0.5…1.0+qx0.5…1.0 |
7.1 Ref. |
≤0.78 |
100A |
|||
|
3×35+px0.5…1.0+qx0.5…1.0 |
8.4 Ref. |
≤0.554 |
125A |
|||
|
4×2.5…35+px0.5…1.0+qx0.5…1.0 |
/(The main conductor cross-sectional area may be selected to match that of the aforementioned single-phase configuration) |
/ |
10-125A |
|||
|
5×2.5…35+px0.5…1.0+qx0.5…1.0 |
|
/ |
10-125A |