UL2263

Application Scenarios

Advantages

• Comprehensive product range catering to diverse application scenarios
• Resistant to extreme temperatures, oils, acids, alkalis, water, abrasion and cracking
• Among the earliest manufacturers to obtain UL certification for the entire EVE and EVJE series
• Authoritative dual certification ensuring barrier-free market access in the US and Canada
• UL conducts quarterly/annual sampling inspections at production facilities to guarantee consistent cable quality

Standard

UL 2263

Certification

 UL & cus certification (EVE, EVJE)

 

Certificate numbers:

E345899-2011-06-24

E345899-2011-06-23

General Specification

Contact OMG Cable Specialists for the latest cable specifications

Cable Characteristics

Performance Request

Item

Request

Test Method

Rated Voltage_

1000V

Rated Temperature

-40~105℃

Conductor Resistance(at 20℃)

6AWG≤1.4Ω/km;8AWG≤2.23Ω/km;22AWG≤56.8Ω/km;

UL2556

15℃Insulation resistance

6AWG≥29GΩ.m;8AWG≥34GΩ.m;22AWG≥67GΩ.m

UL2556

Dielectric

4.0KV AC/1min(6AWG&8AWG),2.0KV AC/1min(22AWG)

UL2556

Bending Radius Min.

≥6 OD.

Flame Test

FT1

UL2556

Insulation tensile strength

Before Aging 5.5Mpa; After Aging(136℃/168H) ≥75%Original

UL2556

Insulation Elongation

Before Aging 200%; After Aging(136℃/168H) ≥75%Original

UL2556

Jacket tensile strength

Before Aging 8.3Mpa; After Aging(136℃/168H) ≥75%Original

UL2556

Jacket Elongation

Before Aging 200%; After Aging(136℃/168H) ≥75%Original

UL2556

Cold Bending Test

-40℃/4H, NO Cracking

UL2556

Hot Shock Test

150℃/1H, NO Cracking

UL2556

 

EVJE

Performance Request

Item

Request

Test Method

Rated Voltage_

300V

Rated Temperature

-40~105℃

 

Conductor Resistance(at 20℃)

16AWG≤14.1Ω/km;22AWG≤56.8Ω/km

UL2556

15℃Insulation resistance

16AWG≥45GΩ.m;22AWG≥67GΩ.m

UL2556

Dielectric

2KV AC/1min

UL2556

Bending Radius Min.

≥6 OD.

UL2556

Flame Test

VW-1

UL2556

Insulation tensile strength_

Before Aging 5.5Mpa; After Aging(136℃/168H) ≥75%Original

UL2556

Insulation Elongation

Before Aging 200%; After Aging(136℃/168H) ≥75%Original

UL2556

Jacket tensile strength

Before Aging 8.3Mpa; After Aging(136℃/168H) ≥75%Original

UL2556

Jacket Elongation

Before Aging 200%; After Aging(136℃/168H) ≥75%Orginal

UL2556

Cold Bending Test

-40℃/4H,NO Cracking

UL2556

Hot Shock Test

150℃/1H,NO Cracking

UL2556

Specifications

Standard UL2263

Specifications

Reference Current

Finished external diameter

Packaging

EVE

3x14AWG+18AWG

16A

Structure designed to meet standards and customer requirements

As per the order or as agreed

3x12AWG+18AWG

24A

3x10AWG+18AWG

32A

2x9AWG+10AWG+18AWG

40A

2x8AWG+10AWG+18AWG

48A

2x6AWG+10AWG+18AWG

70A/80A

EVJE

3x14AWG+18AWG

16A

3x12AWG+18AWG

24A

Signal wire specifications: 16 AWG to 22 AWG, typically 0 to 12 strands.

 